SubjectStandard / regulationScope
Ceramic productTS EN 14411Definition, classification and CE marking of ceramic tiles. Group BIa porcelain (water absorption ≤ 0.5%) for facades.
Ceramic testsEN ISO 10545 seriesDimensions and surface quality (-2), water absorption (-3), breaking strength and modulus of rupture (-4), thermal shock (-9), frost resistance (-12), chemical resistance (-13).
Breaking strengthTS EN ISO 10545-4Cybele Tile mesh-backed porcelain tile: 3,611.1 N in an accredited laboratory test. The EN 14411 group BIa requirement is ≥ 1,300 N, so about 2.8 times higher.
Fire classTS EN 13501-1Reaction-to-fire classification of construction products. Porcelain tile without mesh is class A1 (non-combustible). The mesh and adhesive layer we use is classified B-s1,d0: B, very limited contribution to fire; s1, very little smoke; d0, no flaming droplets.
Wind loadTS EN 1991-1-4Calculation of the wind load acting on facade elements.
SeismicTurkish Building Earthquake Code (2018)Seismic design of non-structural elements, including facade cladding.
Aluminium substructureTS EN 1999-1-1, TS EN 755-2Design of aluminium structures and mechanical properties of extruded profiles.
FixingsTS EN ISO 3506-1Mechanical properties of stainless steel screws and bolts (A2/A4).
Bonded systemsTS EN 12004-1, TS EN 13888Tile adhesives and grouts.
Thermal insulationTS 825Thermal insulation rules for buildings.
Fire regulationTurkish Regulation on Fire Protection of BuildingsRules for exterior cladding and insulation materials.
EN ISO 10545-4 breaking strength test result: 3,611.1 N
Cybele Tile tile reinforced with fibreglass mesh on the back
Pull test on a mesh-backed tile at the facility

CE marking and declaration of performance

CE marking and the declaration of performance (DoP) apply to the ceramic product and are prepared by the manufacturer under EN 14411. The declaration of performance and test reports for Cybele Tile tiles are available on request.

Cybele Tile mesh-backed tile test report (PDF)

The fixing system and the installation service are not subject to CE marking. The safety of the installation is ensured by project-specific structural calculation and inspection.