Technical standards
The standards and regulations we refer to for facade tiles, substructures and installation.
| Subject | Standard / regulation | Scope |
|---|---|---|
| Ceramic product | TS EN 14411 | Definition, classification and CE marking of ceramic tiles. Group BIa porcelain (water absorption ≤ 0.5%) for facades. |
| Ceramic tests | EN ISO 10545 series | Dimensions and surface quality (-2), water absorption (-3), breaking strength and modulus of rupture (-4), thermal shock (-9), frost resistance (-12), chemical resistance (-13). |
| Breaking strength | TS EN ISO 10545-4 | Cybele Tile mesh-backed porcelain tile: 3,611.1 N in an accredited laboratory test. The EN 14411 group BIa requirement is ≥ 1,300 N, so about 2.8 times higher. |
| Fire class | TS EN 13501-1 | Reaction-to-fire classification of construction products. Porcelain tile without mesh is class A1 (non-combustible). The mesh and adhesive layer we use is classified B-s1,d0: B, very limited contribution to fire; s1, very little smoke; d0, no flaming droplets. |
| Wind load | TS EN 1991-1-4 | Calculation of the wind load acting on facade elements. |
| Seismic | Turkish Building Earthquake Code (2018) | Seismic design of non-structural elements, including facade cladding. |
| Aluminium substructure | TS EN 1999-1-1, TS EN 755-2 | Design of aluminium structures and mechanical properties of extruded profiles. |
| Fixings | TS EN ISO 3506-1 | Mechanical properties of stainless steel screws and bolts (A2/A4). |
| Bonded systems | TS EN 12004-1, TS EN 13888 | Tile adhesives and grouts. |
| Thermal insulation | TS 825 | Thermal insulation rules for buildings. |
| Fire regulation | Turkish Regulation on Fire Protection of Buildings | Rules for exterior cladding and insulation materials. |



CE marking and declaration of performance
CE marking and the declaration of performance (DoP) apply to the ceramic product and are prepared by the manufacturer under EN 14411. The declaration of performance and test reports for Cybele Tile tiles are available on request.
Cybele Tile mesh-backed tile test report (PDF)
The fixing system and the installation service are not subject to CE marking. The safety of the installation is ensured by project-specific structural calculation and inspection.
Document request
Write to us to request test reports, declarations of performance or system technical details.