Skip to content

Seismic safety services

We calculate how a ceramic facade will behave under earthquake and wind before installation, and verify it with project-specific testing when needed.

Ceramic facade system section: bracket, profile, insulation and tile

Structural facade report

This is the most important step before testing and installation. We assess the seismic and wind data for the building's location, the ground conditions and the facade geometry together, and calculate whether the profiles, anchors and fixings are adequate.

Structural calculation and DWG drawing

We draw the anchor points and profile layout in DWG format. Preparation usually takes 3–7 working days. This service is charged separately; the price depends on the area and complexity of the facade.

Movable clip system anchor and profile detail
Ceramic facade mock-up: substructure and insulation

Project-specific seismic testing

When needed, a project-specific facade mock-up is built. The anchor structure, profile thickness and porcelain tile are tested together under defined seismic accelerations. These tests require a special rig and laboratory work, so they involve additional cost.

Why us?

The whole chain is in one hand, from tile supply and mesh backing at our facility to structural approval and installation on site. We develop project-specific fixing details for angled and complex geometries.

Request a structural report or DWG details

Send us the facade elevations and building information and we will let you know the timing and price.

WhatsApp+90 850 549 98 48[email protected]Back to top